ARM3L Series Leakage Circuit Breakers ARM3L-160A-4300 4P
Rated Current : 16A、20A、25A、32A、40A、50A、63A、80A、100A、125A
Number Of Poles : 3P/4P
Rated Working Voltage : 400V/690V
Share:
  • Product Overview
  • Environment of use
  • Technical specifications
  • Size structure
  • Download information

Residual current circuit breaker, mainly applicable to AC 50Hz, rated voltage 400V, rated current up to 800A in the distribution network, used to provide indirect contact protection to people, can also be used to prevent fire hazards caused by equipment insulation damage, resulting in ground fault current, and can be used to distribute electrical energy and protect the line and power supply equipment overload and short circuit, but also as the line of infrequent conversion and motor Infrequent switching and motor starting. Conventional leakage protection module with residual current protection circuit breaker work power sampling for two-phase, this series of circuit breakers for three-phase, if the lack of a phase, circuit breaker leakage protection module can still work normally; rated residual action current and maximum disconnection time according to the actual situation on site adjustable; when the phase voltage is reduced to 50V, leakage protection module can still work normally



Description of button indications for earth leakage circuit breakers.

Leakage circuit breaker residual leakage current action value can be set 30mA, 50mA, 100mA, 200mA, 300mA, 500mA, 1000mA and so on, can also be set to limit the action time, respectively, non-delayed and time-delayed type, the optional time of 0.1s, 0.5s and 1s.

0.jpg


Outer packaging information (dimensions Weight)

Model number

Minimum

order

quantity

Product size mm

(L*W*H)

Weight

Packing metho

(wooden box/carton)

Number of boxes

Inner box size cm

(L*W*H)

Outer box size cm

(L*W*H)

Box weight

(g)

ARM3L-160-4300

2000
  • Cardboard box



17.3*13*13.32200

未标题-1.jpg



Accessories and Accessories

ARM6L-125包装.jpg

1-英文.jpg

Ⅰ. The surrounding air temperature state is: -5℃~+40℃

Ⅱ. The altitude of the installation site should not exceed 2000m

Ⅲ. The relative humidity of the air at the installation site should not exceed 50% when the maximum temperature is +40℃, and then there can be higher relative humidity at lower temperatures, such as up to 90% at 20℃. Special measures shall be taken for occasional condensation due to temperature changes.

Ⅳ. Pollution class 3

Ⅴ. The wet and hot band type (TH type) circuit breaker passes the test requirements of IEC60947-2 and GB/T2423.18, and can withstand the effects of humid air, salt spray, oil mist and mold.

Ⅵ. The circuit breaker should be installed in a place where there is no danger of explosion and no conductive dust, not enough to corrode the metal and destroy the insulation

Ⅶ. the circuit breaker should be installed in a place without rain and snow intrusion

Ⅷ. Operating conditions: the circuit breaker passes the test requirements of GB/T 2423.1 and GB/T2423.2, the surrounding air temperature can be as low as -25℃ (ARM1DC/ARM3DC/ARM6DC can provide temperature as low as -40℃, consult our company), as high as +70℃ (more than 40℃ reduced capacity use, please refer to the technical information in the attached sample)

ModelCurrent shell frame

Rated

current

(In)

Use 

Category

PolesUeIcuIcsI△nI△noI△mUiUimpMechanical Endurance

Electrical

safe

life

Flashover distance

(mm)

ARM3L-125M125A16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、Class A3P400V50KA35KAⅠ:100、300、500
Ⅱ:30、100、300
 I△n x50%Icu x25%1000V8KV85001500≯50
ARM3L-125M125A16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、Class A4P400V50KA35KAⅠ:100、300、500
Ⅱ:30、100、300
 I△n x50%Icu x25%1000V8KV85001500≯50
ARM3L-125H125A16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、Class A3P400V85KA50KAⅠ:100、300、500
Ⅱ:30、100、300
 I△n x50%Icu x25%1000V8KV85001500≯50
ARM3L-125H125A16A、20A、25A、32A、40A、50A、63A、80A、100A、125A、Class A4P400V85KA50KAⅠ:100、300、500
Ⅱ:30、100、300
 I△n x50%Icu x25%1000V8KV85001500≯50

Model

Rated current (In)

Poles

Structure size

Dimension(W*L*H1)

Dimensions(W*L*H2)

ARM3L-125M

16A、20A、25A、32A、40A、50A、63A、80A、100A、125A

3P

1667524767317412.jpg

92*150*110

92*150*92

ARM3L-125M

16A、20A、25A、32A、40A、50A、63A、80A、100A、125A

4P

122*150*110

122*150*92

ARM3L-125H

16A、20A、25A、32A、40A、50A、63A、80A、100A、125A

3P

92*150*110

92*150*92

ARM3L-125H

16A、20A、25A、32A、40A、50A、63A、80A、100A、125A

4P

122*150*110

122*150*92