Moulded case circuit breaker manufacturers tell you the selection method of moulded case circuit breaker

Date | 2022-09-27 13:58:03

Widely used in civil construction, defence, mining, industry and agriculture, transport and other fields, moulded case circuit breakers play a huge role in the distribution and transmission of electricity, circuit protection and control, and it is a product with a large volume and wide range of use.


As users do not have a deep or comprehensive understanding of the technical and characteristic requirements of moulded case circuit breakers, certain concepts are particularly susceptible to confusion with each other and misunderstandings and deviations often occur in practical applications. This article describes the problems that tend to arise when users use and select plastic-case circuit breakers. This enables users to make a reasonable choice of moulded case circuit breakers.


The case level rating of a moulded case circuit breaker is the current rating of the largest tripper that can be mounted in a frame and plastic box of the same basic dimensions.


The molded case circuit breaker current rating is the current through which the tripping of the circuit breaker can pass for a long period of time (also known as the tripping rating of the circuit breaker).


Plastic case circuit breaker manufacturers feel that the same series of plastic case circuit breakers have a variety of case rating current, and the same case rating has a variety of rated currents. For example, the DZ20 series has 100, 225, 400, 630, 800, 1250, etc. pannier level rated current, 100 pannier level rated current of 16A, 20A, 25A, 32A, 40A, 50A, 63A, etc. 225A pannier level DZ20-100 and DZ20-225 two shell level have 100A rated current, but due to the circuit breaker Volume and cut-off capacity is different, in the selection must fill the entire shell level rated current within the rated current of the circuit breaker. The current rating classes are selected according to a (1.25) priority factor. On the one hand it is necessary to meet and satisfy the maximum circuit and electrical component current ratings. On the other hand, it is for standardisation to allow for maximum use of diagram lines and processing. Therefore, 3(6), 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 and 160 are specified at the following levels


The integer value of the tripping current is the value of the tripping being adjusted to the movement current. A multiple of the rated current, In, is the value of the operating current. For example, the overcurrent is adjusted to 1.2, 1.3, 5, 10 times the current and recorded as IR = 1.2 in, 1.3 In, 5 In, 10 In, etc. Some electronic trips are now available which have an overload long time delay rated current that is adjustable, but the regulated current is still the rated current, the maximum current that can be passed in the long term.

塑壳断路器

The rated operating current is the actual operating current of the contacts when the circuit breaker is fitted with auxiliary contacts (accessories) working at a specific operating voltage, current 3A or 6A, for circuit control and protection.


The rated insulation voltage of the moulded case circuit breaker manufacturer is the voltage value to which the electrical gap and leakage distance must refer for the design of the circuit breaker. Some circuit breakers do not specify a rated insulation voltage, so the maximum value of the rated operating voltage should be considered as the rated insulation voltage. Under no circumstances should the maximum rated operating voltage exceed the rated insulation voltage. The rated insulation voltage and the frequency test voltage of the circuit breaker are shown in Table 1.


The rated operating voltage is the cut-off capacity and category-related voltage value. The rated working voltage of the moulded case circuit breaker is 50Hz, 380V, but there are also moulded case circuit breakers with 50Hz, 600V and rated working voltage of 380V, 50Hz. Absolutely no supply voltages of 660V or 1140V are allowed.


The rated limit short-circuit interception capacity is the division capacity under the specified conditions. After doing the action in accordance with the prescribed experimental procedures, the circuit breaker is not considered and the rated current continues to be delivered.


The rated operating short-circuit interception capacity is the division capacity under the specified conditions. In accordance with the prescribed test procedure, the circuit breaker shall be considered to continue to deliver its rated current.


The rated control supply voltage is the voltage at which the separation and electrical mechanism accessories are installed on the moulded case circuit breaker. Both AC and DC voltages are available and the selection must show either AC or DC.


At the same time, in order to meet the needs of different users, at present, many domestic circuit breaker manufacturers, the same case class rated current short-circuit cut-off capacity can be divided into different levels. For example, Changshu switchgear factory CM1-100 is divided into C basic (25 ~ 35ka), L standard (35 ~ 50 ~ 75kA), M is a relatively high score type (50), the user must meet the ultimate short circuit blocking capacity of the circuit breaker when choosing, the circuit is expected to short circuit current can meet the requirements.