An introduction to the reliability of moulded case circuit breakers

Date | 2022-08-11 09:13:04

The study of the stability of moulded case circuit breakers is of great importance for the development of society as well as for the individual's life. The stability of moulded-case circuit breakers is examined, as well as the causes of their failure and the basis for the determination of their ageing. In order to improve its stability and perfect its deficiencies, accordingly, useful suggestions are put forward in terms of its selection and application conditions, multifunctional testing equipment, intelligent planning, etc. The improvement in the stability of the circuit breakers is accompanied by an improvement in user experience and well-being.

The benefits of the steady progress of the MCCB are not only personal, but also social and economic. They go far beyond what is known about it, and it is now necessary to understand its functions and benefits, its importance and the need to deal with the proof aspect of its stability. The manufacture of multifunctional test equipment is technically more oriented towards intelligent planning. The stability of its test conditions and the causes of its failure are then investigated step by step, step by step, in terms of its selection and application, which are specifically analysed and discussed by the author.

Stability analysis of moulded-case circuit breakers

To analyse the stability of moulded case circuit breakers, the importance of moulded case circuit breakers must be known, and then some test methods and related aspects of the failure mode of moulded case circuit breakers are discussed, and experimental schemes for moulded case circuit breakers are proposed to verify experimental methods against stability and to propose feasible test conditions:


The importance of examining the operating stability of earth leakage protection

The role of the MCCB demonstrates the importance of examining the stability of the MCCB. Firstly, the leakage protection has the function of a circuit breaker, although leakage protection defects do not often appear and their presentation rules are not fixed, even if a leakage defect occurs, there is no need to worry too much, it will actively block the line and cause the effects of a power failure. It is very important to have a leak-protection function, assuming that stability is not high and that someone may experience a leak situation that could lead to a life-threatening or leaky fire. In addition, having an overcurrent trip function, in addition to a leakage trip function, protects the grid, reduces the amount of maintenance operations and in a sense reduces certain economic costs. Therefore, the study of the stability of low-voltage electrical appliances not only has important scientific significance, but also can produce serious social benefits and certain economic benefits, is an important part of the study of the stability of low-voltage electrical appliances.


Stability check of moulded case circuit breakers

A well-thought-out operating method and operating plan are required, first of all to clarify the operating principle and operating state of the plastic-case circuit breaker. The operating state is divided into two aspects:on the one hand, when there are no leakage defects, the electrical equipment works normally and the leakage protection part does not work; on the other hand, when leakage defects occur, they threaten the personal safety of the electrocutioner and the fire caused by the leakage, therefore the leakage protection part should be sensitive to separate the contacts to block the circuit. In the stability test of the leakage protection, defects such as rejection and misoperation are the main test strategies. The protection success rate R bump can be selected as the stability strategy. When repeating the defect rate verification experiment, a suitable defect rate and number of permissible failures should first be selected to ensure a real and stable effect. However, as far as operational defects are concerned, it is a good choice to select the size of the defect rate λ as a stability strategy.