ARM1E Series Electronic Molded Case Circuit Breaker ARM1E-1250A
Rated Current : 800A、850A、900A、950A、1000A、1050A、1100A、1250A
Number Of Poles : 3P/4P
Rated Working Voltage : 400V/690V
Share:
  • Product Overview
  • Environment of use
  • Technical specifications
  • Size structure
  • Download information

ARM1E series electronic plastic case circuit breakers (hereinafter referred to as circuit breakers) are suitable for infrequent switching and infrequent starting of motors in circuits with AC 50HZ, rated insulation voltage of 1000V, rated working voltage of 400V and rated working current of 1250A.

The circuit breaker has overload long-delay inverse time limit, short-circuit short-delay inverse time limit, short-circuit short-delay fixed time limit, short-circuit instantaneous and undervoltage protection functions as well as residual current protection (optional) phase failure protection function (optional), which can protect the line and power supply equipment from damage, the circuit breaker has complete and precise protection characteristics, which can improve the reliability of power supply and avoid unnecessary power outages, of which "Z, B "type control with communication interface, can be "four remote" to meet the requirements of the control center and automation system.

According to its rated limit short-circuit breaking capacity, the circuit breaker is divided into L type (standard type), M type (higher breaking type) and H type (high breaking type). The circuit breaker has the characteristics of small size, high breaking capacity, short flying arc and vibration resistance. 

The circuit breaker can be installed vertically (i.e., vertical installation), or horizontally (i.e., horizontal installation), and can be installed lying flat.

Circuit breaker with isolation function, the corresponding symbol: "The circuit breaker can not be inverted into the line, that is, only allow 1, 3, 5 connected to the power line 2, 4, 6 connected to the load line.

1-英文.jpg

Ⅰ、The surrounding air temperature state is: -5℃~+40℃

Ⅱ、The altitude of the installation site does not exceed 2000m

Ⅲ、The relative humidity of the air at the installation site does not exceed 50% at the highest temperature of +40℃, and can have a higher relative humidity at lower temperatures, such as up to 90% at 20℃. Special measures should be taken for the occasional condensation due to temperature changes.

Ⅳ、The pollution level is 3

Ⅴ, wet and hot band type (TH type) circuit breakers through IEC60947-2, GB/T2423.18 test requirements, can withstand the effects of humid air, salt spray, oil mist, mold.

Ⅵ、The circuit breaker should be installed in a place where there is no danger of explosion and no conductive dust, not enough to corrode the metal and destroy the insulation

Ⅶ, the circuit breaker should be installed in a place where there is no rain or snow intrusion

Ⅷ、Operating conditions: the circuit breaker passes the test requirements of GB/T 2423.1 and GB/T2423.2, the surrounding air temperature can be as low as -25℃ (ARM1DC/ARM3DC/ARM6DC can provide temperature as low as -40℃, consult our company), as high as +70℃ (more than 40℃ reduced capacity use, see the technical information in the attached sample)


ModelCurrent shell frame

Rated

current

(In)

Use 

Category

PolesUeIcuIcsIcwUiUimpMechanical Endurance

Electrical

safe

life

Flashover distance

(mm)

ARM1E-1250

(800~1250A)

1250A1250A(Ir:800A、850A、900A、950A、1000A、1050A、1100A、1250A Graded regulation)Class B3P400V80KA50KA15KA/1s1000V8KV2500500≯100

Model

Rated current

(In)

Poles

Structure

size

Dimensions(W*L*H1)

Dimensions(W*L*H2)

ARM1E-1250

(800~1250A)

1250A

(Ir:800A、850A、900A、950A、1000A、1050A、1100A、1250A Graded regulation)

3P

1668386545832254.jpg

210*341*195

210*341*137


Scan QR Code and Follow with WeChat Accounts to get all sample books